| Working
pressure |
2
÷ 10 bar |
| Ambient
temperature |
-10
÷ 70 |
| Fluid |
filtered
air 30 μm |
| Bore
size |
032
- 040 - 050 - 063 mm |
| Standard
stroke |
depending
on bore size (refer to codification key) |
| Barrel |
extruded
barrel in aluminium alloy with groove for
flush-mountedsensors |
| Piston
rod |
chromium-plated
steel |
| Functioning
of the locking unit |
passive,
in the absence of signal and/or air supply |
| Min.
pressure |
>
3 bar |
| Holding
force of the piston-rod |
>
3 times the thrust of the cylinder with air
supply 6 bar |
| Max.
speed |
1
m/s |
| Precision
of repeatability |
±
0,3 mm |